Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up. / van Loon, J.; Vervest, A. M. J. S.; van der Vis, H. M. et al.
In: International orthopaedics, Vol. 45, No. 6, 06.2021, p. 1447-1454.Research output: Contribution to journal › Article › Academic › peer-review
}
TY - JOUR
T1 - Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up
AU - van Loon, J.
AU - Vervest, A. M. J. S.
AU - van der Vis, H. M.
AU - Sierevelt, I. N.
AU - Baas, D. C.
AU - Opdam, K. T. M.
AU - Kerkhoffs, G. M. M. J.
AU - Haverkamp, D.
N1 - Publisher Copyright: © 2021, The Author(s).
PY - 2021/6
Y1 - 2021/6
N2 - Purpose: In press-fit total hip arthroplasty (THA), primary stability is needed to avoid micromotion and hereby aseptic loosening, the main reason for early revision. High aseptic loosening revision rates of the seleXys TH+ cup (Mathys Medical) with Ceramys ceramic-on-ceramic (CoC) bearing are seen in literature. Since CoC is presumed to overcome long-term wear-related revisions, the reason for early failure of this cup is important to clarify. The aim is to investigate its ten year outcomes and differentiate between potential causes and identify risk factors for aseptic loosening. Methods: Retrospective screening of a prospectively documented series of 315 THAs was performed. Primary outcome was cumulative incidence of cup revision due to aseptic loosening. Secondary outcomes were component revision and reoperation. Additionally, potential predictive factors for aseptic loosening were evaluated. Results: At the median follow-up of 9.7 years [IQR 4.4; 10.3], 48 TH+ (15.2%) were revised due to aseptic loosening. Competing risk analysis showed a ten year cumulative incidence of cup revision due to aseptic loosening of 15.6% (95% CI 12.0–20.2). Stabilization of early revision rates was observed, following a high rate of respectively 81.3% (n = 39) and 95.8% (n = 46) within the first two and three years. No significant predictive factors for aseptic loosening were found. Conclusion: The ten year results of seleXys TH+ cup with Ceramys CoC bearing showed an unacceptable high aseptic loosening rate, which stabilized over time after a high early failure incidence. This could be attributed to a problem with osseointegration during the transition of primary to definitive stability.
AB - Purpose: In press-fit total hip arthroplasty (THA), primary stability is needed to avoid micromotion and hereby aseptic loosening, the main reason for early revision. High aseptic loosening revision rates of the seleXys TH+ cup (Mathys Medical) with Ceramys ceramic-on-ceramic (CoC) bearing are seen in literature. Since CoC is presumed to overcome long-term wear-related revisions, the reason for early failure of this cup is important to clarify. The aim is to investigate its ten year outcomes and differentiate between potential causes and identify risk factors for aseptic loosening. Methods: Retrospective screening of a prospectively documented series of 315 THAs was performed. Primary outcome was cumulative incidence of cup revision due to aseptic loosening. Secondary outcomes were component revision and reoperation. Additionally, potential predictive factors for aseptic loosening were evaluated. Results: At the median follow-up of 9.7 years [IQR 4.4; 10.3], 48 TH+ (15.2%) were revised due to aseptic loosening. Competing risk analysis showed a ten year cumulative incidence of cup revision due to aseptic loosening of 15.6% (95% CI 12.0–20.2). Stabilization of early revision rates was observed, following a high rate of respectively 81.3% (n = 39) and 95.8% (n = 46) within the first two and three years. No significant predictive factors for aseptic loosening were found. Conclusion: The ten year results of seleXys TH+ cup with Ceramys CoC bearing showed an unacceptable high aseptic loosening rate, which stabilized over time after a high early failure incidence. This could be attributed to a problem with osseointegration during the transition of primary to definitive stability.
KW - Aseptic loosening
KW - Ceramic-on-ceramic
KW - Early failure
KW - Primary stability
KW - Total hip arthroplasty
UR - http://www.scopus.com/inward/record.url?scp=85100203471&partnerID=8YFLogxK
U2 - 10.1007/s00264-020-04895-1
DO - 10.1007/s00264-020-04895-1
M3 - Article
C2 - 33459828
VL - 45
SP - 1447
EP - 1454
JO - International orthopaedics
JF - International orthopaedics
SN - 0341-2695
IS - 6
ER -
ID: 15596691