Standard

Breakfast replacement with a low-glycaemic response liquid formula in patients with type 2 diabetes: a randomised clinical trial. / Stenvers, Dirk J.; Schouten, Lydia J.; Jurgens, Jordy et al.

In: British journal of nutrition, Vol. 112, No. 4, 2014, p. 504-512.

Research output: Contribution to journalArticleAcademicpeer-review

Harvard

APA

Vancouver

Stenvers DJ, Schouten LJ, Jurgens J, Endert E, Kalsbeek A, Fliers E et al. Breakfast replacement with a low-glycaemic response liquid formula in patients with type 2 diabetes: a randomised clinical trial. British journal of nutrition. 2014;112(4):504-512. doi: 10.1017/S0007114514001123

Author

Stenvers, Dirk J. ; Schouten, Lydia J. ; Jurgens, Jordy et al. / Breakfast replacement with a low-glycaemic response liquid formula in patients with type 2 diabetes: a randomised clinical trial. In: British journal of nutrition. 2014 ; Vol. 112, No. 4. pp. 504-512.

BibTeX

@article{43fb3b1c9747485a9c710d517c7e86ae,
title = "Breakfast replacement with a low-glycaemic response liquid formula in patients with type 2 diabetes: a randomised clinical trial",
abstract = "Low-glycaemic index diets reduce glycated Hb (HbA1c) in patients with type 2 diabetes, but require intensive dietary support. Using a liquid meal replacement with a low glycaemic response (GR) may be an alternative dietary approach. In the present study, we investigated whether breakfast replacement with a low-GR liquid meal would reduce postprandial glycaemia and/or improve long-term glycaemia. In the present randomised, controlled, cross-over design, twenty patients with type 2 diabetes consumed either a breakfast replacement consisting of an isoenergetic amount of Glucerna SR or a free-choice breakfast for 3 months. Postprandial AUC levels were measured using continuous glucose measurement at home. After the 3-month dietary period, meal profiles and oral glucose tolerance were assessed in the clinical setting. The low-GR liquid meal replacement reduced the AUC of postprandial glucose excursions at home compared with a free-choice control breakfast (estimated marginal mean 141 (95 % CI 114, 174) v. estimated marginal mean 259 (95 % CI 211, 318) mmol × min/l; P= 0·0002). The low-GR liquid meal replacement also reduced glucose AUC levels in the clinical setting compared with an isoenergetic control breakfast (low GR: median 97 (interquartile range (IQR) 60-188) mmol × min/l; control: median 253 (IQR 162-386) mmol × min/l; P < 0·001). However, the 3-month low-GR liquid meal replacement did not affect fasting plasma glucose, HbA1c or lipid levels, and even slightly reduced oral glucose tolerance. In conclusion, the low-GR liquid meal replacement is a potential dietary approach to reduce postprandial glycaemia in patients with type 2 diabetes. However, clinical trials into the effects of replacing multiple meals on long-term glycaemia in poorly controlled patients are required before a low-GR liquid meal replacement can be adopted as a dietary approach to the treatment of type 2 diabetes",
author = "Stenvers, {Dirk J.} and Schouten, {Lydia J.} and Jordy Jurgens and Erik Endert and Andries Kalsbeek and Eric Fliers and Bisschop, {Peter H.}",
year = "2014",
doi = "10.1017/S0007114514001123",
language = "English",
volume = "112",
pages = "504--512",
journal = "British journal of nutrition",
issn = "0007-1145",
publisher = "Cambridge University Press",
number = "4",

}

RIS

TY - JOUR

T1 - Breakfast replacement with a low-glycaemic response liquid formula in patients with type 2 diabetes: a randomised clinical trial

AU - Stenvers, Dirk J.

AU - Schouten, Lydia J.

AU - Jurgens, Jordy

AU - Endert, Erik

AU - Kalsbeek, Andries

AU - Fliers, Eric

AU - Bisschop, Peter H.

PY - 2014

Y1 - 2014

N2 - Low-glycaemic index diets reduce glycated Hb (HbA1c) in patients with type 2 diabetes, but require intensive dietary support. Using a liquid meal replacement with a low glycaemic response (GR) may be an alternative dietary approach. In the present study, we investigated whether breakfast replacement with a low-GR liquid meal would reduce postprandial glycaemia and/or improve long-term glycaemia. In the present randomised, controlled, cross-over design, twenty patients with type 2 diabetes consumed either a breakfast replacement consisting of an isoenergetic amount of Glucerna SR or a free-choice breakfast for 3 months. Postprandial AUC levels were measured using continuous glucose measurement at home. After the 3-month dietary period, meal profiles and oral glucose tolerance were assessed in the clinical setting. The low-GR liquid meal replacement reduced the AUC of postprandial glucose excursions at home compared with a free-choice control breakfast (estimated marginal mean 141 (95 % CI 114, 174) v. estimated marginal mean 259 (95 % CI 211, 318) mmol × min/l; P= 0·0002). The low-GR liquid meal replacement also reduced glucose AUC levels in the clinical setting compared with an isoenergetic control breakfast (low GR: median 97 (interquartile range (IQR) 60-188) mmol × min/l; control: median 253 (IQR 162-386) mmol × min/l; P < 0·001). However, the 3-month low-GR liquid meal replacement did not affect fasting plasma glucose, HbA1c or lipid levels, and even slightly reduced oral glucose tolerance. In conclusion, the low-GR liquid meal replacement is a potential dietary approach to reduce postprandial glycaemia in patients with type 2 diabetes. However, clinical trials into the effects of replacing multiple meals on long-term glycaemia in poorly controlled patients are required before a low-GR liquid meal replacement can be adopted as a dietary approach to the treatment of type 2 diabetes

AB - Low-glycaemic index diets reduce glycated Hb (HbA1c) in patients with type 2 diabetes, but require intensive dietary support. Using a liquid meal replacement with a low glycaemic response (GR) may be an alternative dietary approach. In the present study, we investigated whether breakfast replacement with a low-GR liquid meal would reduce postprandial glycaemia and/or improve long-term glycaemia. In the present randomised, controlled, cross-over design, twenty patients with type 2 diabetes consumed either a breakfast replacement consisting of an isoenergetic amount of Glucerna SR or a free-choice breakfast for 3 months. Postprandial AUC levels were measured using continuous glucose measurement at home. After the 3-month dietary period, meal profiles and oral glucose tolerance were assessed in the clinical setting. The low-GR liquid meal replacement reduced the AUC of postprandial glucose excursions at home compared with a free-choice control breakfast (estimated marginal mean 141 (95 % CI 114, 174) v. estimated marginal mean 259 (95 % CI 211, 318) mmol × min/l; P= 0·0002). The low-GR liquid meal replacement also reduced glucose AUC levels in the clinical setting compared with an isoenergetic control breakfast (low GR: median 97 (interquartile range (IQR) 60-188) mmol × min/l; control: median 253 (IQR 162-386) mmol × min/l; P < 0·001). However, the 3-month low-GR liquid meal replacement did not affect fasting plasma glucose, HbA1c or lipid levels, and even slightly reduced oral glucose tolerance. In conclusion, the low-GR liquid meal replacement is a potential dietary approach to reduce postprandial glycaemia in patients with type 2 diabetes. However, clinical trials into the effects of replacing multiple meals on long-term glycaemia in poorly controlled patients are required before a low-GR liquid meal replacement can be adopted as a dietary approach to the treatment of type 2 diabetes

U2 - 10.1017/S0007114514001123

DO - 10.1017/S0007114514001123

M3 - Article

C2 - 25091284

VL - 112

SP - 504

EP - 512

JO - British journal of nutrition

JF - British journal of nutrition

SN - 0007-1145

IS - 4

ER -

ID: 2450120